![]() ![]() Note for newer products, such as the USB-1608G series and USB-200 series, you set Misc Option to Misc Option (all four of them) to -1. You can also take this newly edited CB.CFG file and deploy it to another computer. Just run your program.Īlso do not update the unit to be serial number 0 as it will then need to come back here for reprogramming. Once this is done, you can never run InstaCal again as it will destroy this change. If you add another, it would not know which one to use. But again, this only works for one device of this type. ![]() What setting Misc Option to 0 does is it informs the driver that it should use any USB-DIO96H it finds and ignore the serial number. Basically removing what you have just accomplished. If you do, it will delete the device stating that unit is no longer installed and replace it with the unit that is attached. Misc Option: xxx (where xxx is an integer between 1 and 255.)Ĭhange the integer to 0 and exit the file. Open it with Notepad.exe or a similar text editor. For Windows XP, it is located in C:\Program files\Measurement Computing\DAQ folder. To do this, you will need to manually update the InstaCal configuration file called CB.CFG. If you have more than one unit then this will not work and you must run InstaCal to change the unit/update the serial number. However, it will only work if you have ONLY ONE USB-DIO96H in the system. There is a way around having to run InstaCal every time you swap a USB-DIO96H. This application note uses the USB-DIO96H as an example. This application note uses the USB-DIO96H as an example. Swapping an MCC device and not having to run InstaCal every time. Swapping an MCC device and not having to run InstaCal every time. Please consult Windows© Installer SDK for additional documentation on the command line syntax. There are many command line Windows© installer options you can use, though this application note does not address them, you can see what they are by typing in the command line: InstaCal.msi /? To launch InstaCal silently, call it via command line syntax: You will need all these files for InstaCal to function correctly. When it is finished, 7-Zip will create a new folder in the folder where you put Icalsetup.exe, containing the following files and folders: To unzip it into its component parts, run 7-Zip, select the file, and then click on Extract. This file is actually a zipped file set to execute. Install 7-Zip and follow the on screen prompts.ĭownload the InstaCal installer from our website: ![]() To get started, you will need third party software to extract the InstaCal MSI installer from our download. However, depending on your application and MCC hardware, you can copy your configuration file (CB.CFG) to the target computer. Running InstaCal cannot be done in a silent mode. By focusing on your needs and requirements, we strive to provide you with the finest calibration Services.This KB article explains how to silently install InstaCal, but it does not run InstaCal. Our goal at Instacal is to provide professional service at the best turn-around time and exceed the expectations of our clients. ![]() Our expert team can help you with Quality Management System on special project assignments, continuing programs or ‘On-demand’ requirements using our calibration lab accredited as per ISO 17025:2005. Ltd., is backed with skilled professionals with a proficiency in calibration of Electro-technical, mechanical and thermal equipment as well as providing technical support as and when required. Instacal, a sister concern of Transerect Testing and Commissioning Engineers Pvt. Calibration Certificates issued by the Laboratory facilitates traceability to National or International standards. High accuracy master equipment, trained personnel, validated Standard Operating Procedures (SOPs)
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |